Installation Instructions
Styles and parts vary by model.
English
E1
One Handle Shower Only Valve Trim with Rainshower Showerhead
Model Number
Installation Date
For Warranty Support
INS2154B - 8/13
INS2154B - 8/13
©2013 Moen Incorporated www.moen.com
Care Instructions
To preserve the finish on the metallic parts of your Moen faucet, apply non-abrasive wax, such as car wax. Any
cleaners should be rinsed off immediately.
English
E12
One Handle Tub/Shower Only Valve Trim with Rainshower Showerhead
Hot/cold reversed Lines reversed/ Hot/cold reversed Rotate cartridge stem 180˚
cartridge installed so that the notch is facing
upside down down towards the drain.
No water/low flow One or both No water/low flow Turn both water supply valves
supplies not on counterclockwise to the on
to the unit position
Leak or drip Grommets not Leak/drip from spout Replace cartridge
from spout sealing properly
Only hot/no cold – Balancing spool Only hot/no cold – Replace cartridge
Only cold/no hot stuck Only cold/no hot
Stacking (Water Choice of pipe/ Water comes out of spout Change pipe to IPS or
comes out of the distance between and showerhead at the copper/distance from
showerhead during valve and showerhead same time showerhead and valve
tub fill mode) less than 46"/multiple moved to at least 46"/
elbows/anything change or remove anything
restricting flow of restrictive
water exiting valve
Flow restriction Water comes out of spout Remove tub spout and flush
between valve and and showerhead at the out debris – Replace
tub spout same time causing undersized line or fittings
restriction
Valve installed Remove cartridge and verify Remove valve and reinstall
upside down that the outlet hole is in in the proper orientation
proper location (should be
down). "Up" is on the top
of the valve
Restricted Handle (more In the off position, able to Remove handle, rotate 180˚,
temperature range common in knob turn the handle both re-install
models) is installed clockwise and
upside down counterclockwise
Temperature limit Remove handle and Position temperature limit
stop out of position see Step 5.3 stop to desired temperature
position
Not able to install Valve installed too far Handle does not install Contact Moen for assistance.
handle/handle back from finished
rubs up against wall
escutcheon
Handle is hard Cartridge stem is Difficult movement from Replace cartridge
to turn difficult to rotate handle or lubricate
For further assistance, contact Moen at:
USA: 1-800-289-6636 or visit www.moen.com
Canada: 1-800-465-6130 or visit www.moen.ca
6. Post Installation - Troubleshooting Guide
Problem Possible To Diagnose Remedy
Cause
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Installation Instructions

Installation Instructions Styles and parts vary by model.EnglishE1One Handle Shower Only Valve Trim with Rainshower ShowerheadModel NumberInstallation

Page 2

EspañolS6EspañolS7 78” (1981mm)45-48”(1143-1219mm)Sólo regaderaEl brazo de la regadera se debe colocar 78 pulgadas sobreel suelo de la cabina de la

Page 3

Si se trata de una insta-lación sólo para laregadera, vaya al paso 4.4.Los surtidores IPS (roscados)están diseñados para atornillarse en un tubo conro

Page 4 - 78” (1981mm)

S10S11EspañolEspañol 2- + DDDJK113L5.3DJLK5.4 LN M 5.5Garantía limitada de por vida de Moen Los productos Moen han sido fabricados bajo las más estric

Page 5 - Go To Step 4.1

FrançaisF1Un regulador de válvula con manija para regadera con cabezal de laregadera de lluviaINS2154B - 8/13FrançaisGarniture de soupape de douche/ba

Page 6 - Tub/Shower Installation

Table des matièresPièces de douche/baignoire fournies ...F3Pièces fournies po

Page 7 - Instrucciones de instalación

FrançaisF4F5Pipe JointCompoundBrosse métallique Tournevis àpointe cruciforme Coupe-tubeClé à molette CrescentRuban à mesurerLunettes desécurité Thermo

Page 8

FrançaisF6FrançaisF7 78” (1981mm)45-48”(1143-1219mm)Douche seulementLe centre de la soupape doit être situé de 45 à 48 po au-dessus du plancher de l

Page 9

C D NON OUIFrançaisF84. Installation de la garniture de douche/baig

Page 10 - 3/4"

F10F11FrançaisFrançais 2- + DDDJK113L5.3DJLK5.4 LN M 5.5Garantie à vie limitée MoenLes produits Moen ont été fabriqués selon les normes de qualité et

Page 11 - Vaya al Paso 4.1

Table of ContentsShower Only Parts Supplied ...E3Rough-in P

Page 12 - CALIENTE

EnglishE4Pipe JointCompoundWire BrushPhillips ScrewdriverTube CutterCrescent WrenchMeasuring TapeSafety GlassesThermometerThread Seal TapeLead-free So

Page 13 - Directives d’installation

Use 1/2" Copper orIPS Pipe Only78" (1981mm)32" (813mm)6" (152mm) Min.11" (229mm) Max.EnglishE6 78” (1981mm)45-48”(1143-

Page 14 - Table des matières

EnglishE84. Installing Your Moen Tub/Shower Trim2H1Thread Seal TapeWrap thread seal tapearound the threads of theshower arm (H) then screwthe arm into

Page 15

E10E11EnglishEnglish 2- + DDDJK113LRemove the lever (L) andlever handle adapter (J).Note the position of the stop.Position the adjustable tem-peratur

Page 16 - Utiliser un tuyau de 1/2 po

EspañolS1Un regulador de válvula con manija para regadera con cabezal de la regadera de lluviaINS2154B - 8/13EspañolUn regulador de válvula con manija

Page 17 - Ruban d'étanchéité

Tabla de contenidoPiezas suministradas para la tina/regadera.....S3Piezas suministradas s

Page 18 - Français

EspañolS4EspañolS5Pipe JointCompoundCepillo de alambreDesarmador de cruzCortatubosLlave ajustableCinta métricaGafas deseguridadTermómetroCinta para se

Comments to this Manuals

No comments